    Thank you for your assistance in completing the tower lightning protection project. Your company's service is very considerate and technologically advanced, especially the flexible grounding body earthing project, which greatly reduces our cost and time, and I hope to have the opportunity to cooperate again.
Contact Person : cody
Phone Number : 86-17349642793
Whatsapp : +8617349642793

100ka Lightning Spd 3 Phase Ac Surge Protector

Place of Origin China
Brand Name HAMMOND
Certification ISO9001
Model Number HDS-B100
Minimum Order Quantity 50
Price Negotiable
Delivery Time 8 days
Payment Terms L/C, T/T

Contact me for free samples and coupons.

Whatsapp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
Color Red Product Name Lightning Protection Box
Maximum Continuous Operating Voltage Uc 385V Contact Material Fiber Glass Reinforced Plastic
Maximum Discharging Cu 100KA Nominal Discharging C 60KA
Leave a Message
Product Description

Ac Spd 385v Surge Protection Device

 

HDS-B Series surge protective device (SPD) is designed to protect AC 50/60 HZ and 0-380 V power supply systems (such as TN-S, TN-C-S, TT, IT,etc.) The lightning stroke equipotential bonding design meets the IEC61643-1 and GB18802.1 standards. The outside coating attaches to the 35 mm electrical tracks, and the product has built-in auto-release device in case of breakdowns. When the SPD is breakdown, caused by the overcurrent and overheating, the fail part will release from the grid automatically. At the same time, the indicator will glow from green light (normal) to red light (error), and SPD can be replaced under operating voltage.
Specification
Technical Parameters
HDS-B100
Rated Operating Voltage(Un)V
220V / 380V
Maximum Continuous Operating Voltage (Uc)V
385V / 420V
Nominal Discharge Current(8/20μs)KA
60
Maximum Discharge Current(8/20μs)KA
100
Response Time ns
25
Cross Section Area of L/N Cable L/N(mm²)
16, 25
Fuse or Switch Model(A)
63A
Operating Environment Temperature ℃
-40℃~+85℃
Installation
Standard Rail 35mm
Material of Outside Coating
Fiber Glass Reinforced Plastic
100ka Lightning Spd 3 Phase Ac Surge Protector 0